HCM-BROD-0871-C49
PDM-507 ™
PDM-507 ™
ATCC determines the biosafety level of a material based on our risk assessment as guided by the current edition of Biosafety in Microbiological and Biomedical Laboratories (BMBL), U.S. Department of Health and Human Services. It is your responsibility to understand the hazards associated with the material per your organization’s policies and procedures as well as any other applicable regulations as enforced by your local or national agencies.
ATCC highly recommends that appropriate personal protective equipment is always used when handling vials. For cultures that require storage in liquid nitrogen, it is important to note that some vials may leak when submersed in liquid nitrogen and will slowly fill with liquid nitrogen. Upon thawing, the conversion of the liquid nitrogen back to its gas phase may result in the vial exploding or blowing off its cap with dangerous force creating flying debris. Unless necessary, ATCC recommends that these cultures be stored in the vapor phase of liquid nitrogen rather than submersed in liquid nitrogen.
Basic research, compound screening.
ICD-10-CM code: C49 malignant neoplasm of soft tissue Epithelial sarcoma
See associated clinical data for patient profile information if available.
https://portal.gdc.cancer.gov/
https://hcmi-searchable-catalog.nci.nih.gov/model/HCM-BROD-0871-C49
Next-generation cancer model from the Human Cancer Models Initiative (HCMI). Refer to the following websites for additional information on this model including protocols, clinical information, and bioinformatics data.
https://ocg.cancer.gov/programs/hcmi/resources
https://portal.gdc.cancer.gov/
https://hcmi-searchable-catalog.nci.nih.gov/model/HCM-BROD-0871-C49
If use of this culture results in a scientific publication, it should be cited in that manuscript in the following manner: HCM-BROD-0871-C49 (ATCC PDM-507™). Additionally, please acknowledge the HCMI as follows: “We used models and data derived by the Human Cancer Models Initiative (HCMI) https://ocg.cancer.gov/programs/HCMI; dbGaP accession number phs001486.”
50% RETM+ 50% M87+ Fresh Additives
RETM Media:
50% Hams F-12 (Thermo, Cat#11765-054) + 50% Medium 199 Earle's Salts (Thermo, Cat#11150-059) + 5% FBS (ATCC 30-2020) + 3.3 μg/mL Bovine Serum Albumin (Sigma, Cat#A8412) + 10 μg/mL Insulin (Thermo, Cat#12585-014) + 0.1 mM HEPES (Gibco, Cat#15630-080) + 100 ng/mL Cholera Toxin (ATCC MD-8073) + 1X RETM Supplement Mix (10X RETM Supplement Mix: 12 ng/mL 4-Aminobenzoic Acid (Sigma, Cat#A9878-5G) + 25 ng/mL Calciferol (Sigma, Cat#V-024-1ML) + 40 ng/ml Cholesterol (Sigma, Cat#C3045) + 3.5 μg/mL Choline Chloride (Cytiva, Cat#SH30529.01) + 330 ng/mL Folic Acid (J.T. Baker, Cat#5635-02) + 2 mM L-Glutamine (ATCC 30-2214) + 0.5 mg/mL Hydrocortisone (Sigma, H0888) + 1.75 mg/mL Hypoxanthine (Thermo, Cat#A11481.06) + 4.5 μg/mL i Inositol (Thermo, Cat#122261000) + 12 ng/mL L-Ascorbic Acid (Sigma, Cat#A4544), + 5 μg/mL Linoleic Acid (Sigma, Cat#L1012) + 50 ng/mL Lipoic Acid (Sigma, Cat#T1395) + 25 ng/mL Ribose (Sigma, Cat#R9629) + 125 ng/mL Selenious Acid (Sigma, Cat#012574.06) + 8 ng/mL Thiamine HCI (Sigma, Cat#V-014-1ML) + 3 ng/mL Tocopherol Phosphate (Sigma, Cat#T2020) + 75 ng/mL Uracil (Sigma, Cat#U1128) + 350 ng/mL Vitamin B12 (Sigma, Cat#V6629) + 85 ng/mL Xanthine (Sigma, Cat#X4002) + 1280 ng/mL 3,3',5-Triiodo-L- thyronine (Sigma, Cat#T5516) + 50 ng/mL β-estradiol (Sigma, Cat#E2257) + 500 μg/mL O-Phosphorylethanolamine (Sigma, Cat#P0503)
M87 Media:
DMEM:F12 (ATCC 30-2006) + 2% FBS (ATCC 30-2020) + 1% ITS (Thermo, Cat#41400-045) + 0.5 ng/mL Cholera Toxin (ATCC MD-8051) + 1X M87 50X Cocktail (0.3 µg/mL Hydrocortisone (Sigma, H0888) + 50 µM Ethanolamine (Sigma, Cat#411000) + 50 μM O-Phosphorylethanolamine (Sigma, Cat#P0503) + 5 nM 3,3',5-Triiodo-L¬ thyronine (Sigma, Cat#T5516) + 0.5 nM β-estradiol (Sigma, Cat#E2257))
Add Fresh: 2.5 μM lsoprenaline Hydrochloride (Sigma, Cat#I5627-5G) + 5 μg/mL Apo-transferrin (ATCC MD-8053)+ 2.75 ng/mL EGF (Thermo, Cat#PHG0311) + 6 ng/mL L-Glutathione Reduced (Sigma, Cat#G6013)
To ensure the highest level of viability, thaw the vial and initiate the culture as soon as possible upon receipt. If upon arrival, continued storage of the frozen culture is necessary, it should be stored in liquid nitrogen vapor phase and not at 70°C. Storage at 70°C will result in loss of viability.
Complete growth media containing 10% DMSO (ATCC 4-X).
Note: Lot's manufactured by ATCC after May 2020 do not have cholera toxin in cryopreservation media.
TH01: 9
D5S818 12, 13
D13S317: 8, 12
D7S820: 10, 11
D16S539: 11, 13
CSF1PO: 19
Amelogenin: X
vWA: 16, 17
TPOX: 8
The product is provided 'AS IS' and the viability of ATCC® products is warranted for 30 days from the date of shipment, provided that the customer has stored and handled the product according to the information included on the product information sheet, website, and Certificate of Analysis. For living cultures, ATCC lists the media formulation and reagents that have been found to be effective for the product. While other unspecified media and reagents may also produce satisfactory results, a change in the ATCC and/or depositor-recommended protocols may affect the recovery, growth, and/or function of the product. If an alternative medium formulation or reagent is used, the ATCC warranty for viability is no longer valid. Except as expressly set forth herein, no other warranties of any kind are provided, express or implied, including, but not limited to, any implied warranties of merchantability, fitness for a particular purpose, manufacture according to cGMP standards, typicality, safety, accuracy, and/or noninfringement.
This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use. Any proposed commercial use is prohibited without a license from ATCC.
While ATCC uses reasonable efforts to include accurate and up-to-date information on this product sheet, ATCC makes no warranties or representations as to its accuracy. Citations from scientific literature and patents are provided for informational purposes only. ATCC does not warrant that such information has been confirmed to be accurate or complete and the customer bears the sole responsibility of confirming the accuracy and completeness of any such information.
This product is sent on the condition that the customer is responsible for and assumes all risk and responsibility in connection with the receipt, handling, storage, disposal, and use of the ATCC product including without limitation taking all appropriate safety and handling precautions to minimize health or environmental risk. As a condition of receiving the material, the customer agrees that any activity undertaken with the ATCC product and any progeny or modifications will be conducted in compliance with all applicable laws, regulations, and guidelines. This product is provided 'AS IS' with no representations or warranties whatsoever except as expressly set forth herein and in no event shall ATCC, its parents, subsidiaries, directors, officers, agents, employees, assigns, successors, and affiliates be liable for indirect, special, incidental, or consequential damages of any kind in connection with or arising out of the customer's use of the product. While reasonable effort is made to ensure authenticity and reliability of materials on deposit, ATCC is not liable for damages arising from the misidentification or misrepresentation of such materials.
Please see the material transfer agreement (MTA) for further details regarding the use of this product. The MTA is available at www.atcc.org.
This material is subject to the following restrictions in addition to those outlined in the ATCC Material Transfer Agreement:
For information on obtaining additional rights, please contact:
ATCC Licensing
Email: [email protected]