- Product category
-
Bacteria
- Classification
- Enterobacteriaceae, Escherichia
- Strain designation
- EDL 933
- Type strain
- No
- Genome sequenced strain
- Yes
- Isolation source
- Derived from existing strain, CDC EDL 933 (ATCC 43895)
- Applications
-
Enteric disease researchInfectious disease research
- Product format
- Frozen
- Storage conditions
-
-80°C or colder
Documentation
ATCC determines the biosafety level of a material based on our risk assessment as guided by the current edition of Biosafety in Microbiological and Biomedical Laboratories (BMBL), U.S. Department of Health and Human Services. It is your responsibility to understand the hazards associated with the material per your organization’s policies and procedures as well as any other applicable regulations as enforced by your local or national agencies.
ATCC highly recommends that appropriate personal protective equipment is always used when handling vials. For cultures that require storage in liquid nitrogen, it is important to note that some vials may leak when submersed in liquid nitrogen and will slowly fill with liquid nitrogen. Upon thawing, the conversion of the liquid nitrogen back to its gas phase may result in the vial exploding or blowing off its cap with dangerous force creating flying debris. Unless necessary, ATCC recommends that these cultures be stored in the vapor phase of liquid nitrogen rather than submersed in liquid nitrogen.
Detailed product information
General
- Specific applications
-
Enteric Research
- Preceptrol
- No
Characteristics
- Serotype
- O157:H7:K-
- Comments
-
University of Wisconsin genome project strainGenome sequenced strainNot available for International Distribution
Handling information
- Medium
- Temperature
-
37°C
- Atmosphere
-
Aerobic
- Handling procedure
-
- Open the freeze-dried vial according to enclosed instructions.
- Using a single tube of #3 broth (5 to 6 mL), withdraw approximately 0.5 to 1.0 mL with a Pasteur or 1.0 mL pipette. Rehydrate the entire pellet.
- Aseptically transfer this aliquot back into the broth tube. Mix well.
- Use several drops of the suspension to inoculate a #3 slant, and/or plate.
- Incubate all tubes and plates at 37°C for 24 hours.
- Handling notes
- Additional information on this culture is available on the ATCC® web site at www.atcc.org.
Quality control specifications
- Verification method
-
Whole-genome Sequencing
History
- Deposited as
- Escherichia coli (Migula) Castellani and Chalmers
- Depositors
- G Plunkett
- Chain of custody
- ATCC <-- G Plunkett <-- C. Kaspar
- Special collection
-
NCRR Contract
- Cross references
-
GenBank AF071034 LEE element sequenceGenBank AF074613 pO157 plasmid sequenceGenBank AF125520 933W bacteriophage sequenceGenBank AE005174 Escherichia coli O157:H7 EDL933, complete genomeGenBank DQ272420.1 Escherichia coli strain ATCC 700927 clone 2 putative outer membrane lipoprotein (nlpD) gene, partial cds; and truncated sigma 38 factor (rpoS) gene, complete cdsGenBank DQ272419.1 Escherichia coli strain ATCC 700927 clone 1 putative outer membrane lipoprotein (nlpD) gene, partial cds; and truncated sigma 38 factor (rpoS) gene, complete cdsGenBank CP008958.1 Escherichia coli O157:H7 str. EDL933 plasmid, complete sequenceGenBank CP008957.1 Escherichia coli O157:H7 str. EDL933, complete genome
Legal disclaimers
- Intended use
- This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use.
- Warranty
-
The product is provided 'AS IS' and the viability of ATCC® products is warranted for 30 days from the date of shipment, provided that the customer has stored and handled the product according to the information included on the product information sheet, website, and Certificate of Analysis. For living cultures, ATCC lists the media formulation and reagents that have been found to be effective for the product. While other unspecified media and reagents may also produce satisfactory results, a change in the ATCC and/or depositor-recommended protocols may affect the recovery, growth, and/or function of the product. If an alternative medium formulation or reagent is used, the ATCC warranty for viability is no longer valid. Except as expressly set forth herein, no other warranties of any kind are provided, express or implied, including, but not limited to, any implied warranties of merchantability, fitness for a particular purpose, manufacture according to cGMP standards, typicality, safety, accuracy, and/or noninfringement.
- Disclaimers
-
This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use. Any proposed commercial use is prohibited without a license from ATCC.
While ATCC uses reasonable efforts to include accurate and up-to-date information on this product sheet, ATCC makes no warranties or representations as to its accuracy. Citations from scientific literature and patents are provided for informational purposes only. ATCC does not warrant that such information has been confirmed to be accurate or complete and the customer bears the sole responsibility of confirming the accuracy and completeness of any such information.
This product is sent on the condition that the customer is responsible for and assumes all risk and responsibility in connection with the receipt, handling, storage, disposal, and use of the ATCC product including without limitation taking all appropriate safety and handling precautions to minimize health or environmental risk. As a condition of receiving the material, the customer agrees that any activity undertaken with the ATCC product and any progeny or modifications will be conducted in compliance with all applicable laws, regulations, and guidelines. This product is provided 'AS IS' with no representations or warranties whatsoever except as expressly set forth herein and in no event shall ATCC, its parents, subsidiaries, directors, officers, agents, employees, assigns, successors, and affiliates be liable for indirect, special, incidental, or consequential damages of any kind in connection with or arising out of the customer's use of the product. While reasonable effort is made to ensure authenticity and reliability of materials on deposit, ATCC is not liable for damages arising from the misidentification or misrepresentation of such materials.
Please see the material transfer agreement (MTA) for further details regarding the use of this product. The MTA is available at www.atcc.org.
Frequently Asked Questions
References
Curated Citations
Perna NT, et al. Molecular evolution of a pathogenicity island from enterohemorrhagic Escherichia coli O157:H7. Infect. Immun. 66: 3810-3817, 1998. PubMed: 9673266
Plunkett G, et al. Sequence of Shiga toxin 2 phage 933W from Escherichia coli O157:H7: Shiga toxin as a phage late-gene product. J. Bacteriol. 181: 1767-1778, 1999. PubMed: 10074068
Burland V, et al. The complete DNA sequence and analysis of the large virulence plasmid of Escherichia coli O157:H7. Nucleic Acids Res. 26: 4196-4204, 1998. PubMed: 9722640
Perna NT, et al. Genome sequence of enterohemorrhagic Escherichia coli O157:H7. Nature 409: 529-533, 2001. PubMed: 11206551
Guy Plunkett, personal communication
For product-related inquiries and issues, contact Product Experience:
Hours of Operation
US Eastern Time