- Product category
-
Bacteria
- Product type
-
NGS standard
- Components
-
8.3% Bacteriodes fragilis (ATCC 25285)8.3% Phocaeicola vulgatus (ATCC 8482)8.3% Bifidobacterium adolescentis (ATCC 15703)8.3% Clostridioides difficile (ATCC 9689)8.3% Enterococcus faecalis (ATCC 700802)8.3% Lactobacillus plantarum (ATCC BAA-793)8.3% Enterobacter cloacae (ATCC 13047)8.3% Escherichia coli (ATCC 700926)8.3% Helicobacter pylori (ATCC 700392)8.3% Salmonella enterica subsp. enterica (ATCC 9150)8.3% Yersinia enterocolitica (ATCC 27729)8.3% Fusobacterium nucleatum subsp. nucleatum (ATCC 25586)
- Applications
-
BioinformaticsEnteric disease researchInfectious disease researchMicrobiome researchNext-generation sequencing
- Product format
- Freeze-dried
- Storage conditions
-
2°C to 8°C
Documentation
ATCC determines the biosafety level of a material based on our risk assessment as guided by the current edition of Biosafety in Microbiological and Biomedical Laboratories (BMBL), U.S. Department of Health and Human Services. It is your responsibility to understand the hazards associated with the material per your organization’s policies and procedures as well as any other applicable regulations as enforced by your local or national agencies.
ATCC highly recommends that appropriate personal protective equipment is always used when handling vials. For cultures that require storage in liquid nitrogen, it is important to note that some vials may leak when submersed in liquid nitrogen and will slowly fill with liquid nitrogen. Upon thawing, the conversion of the liquid nitrogen back to its gas phase may result in the vial exploding or blowing off its cap with dangerous force creating flying debris. Unless necessary, ATCC recommends that these cultures be stored in the vapor phase of liquid nitrogen rather than submersed in liquid nitrogen.
Detailed product information
General
- Specific applications
-
NGS Standards enable the optimization of metagenomics workflows and research applications, providing reliable comparative data while improving assay consistency.
This product is ideal for studies on the gut microbiome, research on the effects of dysbiosis on human health, assay development, and as a daily run control for molecular diagnostics and microbiome applications.
Characteristics
- Genome sequenced strain
- Yes
- Comments
-
NGS Standards are mock
microbial communities that mimic mixed metagenomic samples. This
product is prepared as an even mixture of whole cells and
comprises
fully sequenced, characterized, and authenticated
bacterial species observed in normal and atypical gut microbial
communities. Each
order for this product is provided with access to run 10
analyses on One Codex, the leading bioinformatics platform for
microbial genomics and metagenomics.
Specification Range: 2.4x108 cells/vial ± 1 log*
*Whole cell concentrations indicate ATCC manufacturing specifications and are provided as a reference only
Handling information
- Handling procedure
-
- Add 1 mL of cold PBS to the lyophilized pellet.
- Allow the pellet to dissolve at least for two minutes; keep the vial on ice to prevent cell lysis.
- After reconstitution, mix the product gently and aliquot 200 µL into five Eppendorf tubes.
- Centrifuge for 10 min at 10,000xg at 4°C.
- Carefully discard the supernatant without disrupting the pellet.
- Use the pellet for DNA extraction immediately or freeze the pellet for use at later time
History
- Special collection
-
NGS Standards
Legal disclaimers
- Intended use
- This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use.
-
Purchase of this product will include limited use access to the One Codex platform for metagenomic analysis of ATCC microbiome products. By purchasing this product, you consent and agree to allow ATCC to securely transfer sales and end users’ data related to this product to One Codex. Provision of One Codex access, storage, management of sequencing data, and the interpretation and accuracy of analytical results provided by One Codex are the responsibility of One Codex and not ATCC. End users should visit onecodex.com for their complementary metagenomic data analysis.
- Warranty
-
The product is provided 'AS IS' and the viability of ATCC® products is warranted for 30 days from the date of shipment, provided that the customer has stored and handled the product according to the information included on the product information sheet, website, and Certificate of Analysis. For living cultures, ATCC lists the media formulation and reagents that have been found to be effective for the product. While other unspecified media and reagents may also produce satisfactory results, a change in the ATCC and/or depositor-recommended protocols may affect the recovery, growth, and/or function of the product. If an alternative medium formulation or reagent is used, the ATCC warranty for viability is no longer valid. Except as expressly set forth herein, no other warranties of any kind are provided, express or implied, including, but not limited to, any implied warranties of merchantability, fitness for a particular purpose, manufacture according to cGMP standards, typicality, safety, accuracy, and/or noninfringement.
- Disclaimers
-
This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use. Any proposed commercial use is prohibited without a license from ATCC.
While ATCC uses reasonable efforts to include accurate and up-to-date information on this product sheet, ATCC makes no warranties or representations as to its accuracy. Citations from scientific literature and patents are provided for informational purposes only. ATCC does not warrant that such information has been confirmed to be accurate or complete and the customer bears the sole responsibility of confirming the accuracy and completeness of any such information.
This product is sent on the condition that the customer is responsible for and assumes all risk and responsibility in connection with the receipt, handling, storage, disposal, and use of the ATCC product including without limitation taking all appropriate safety and handling precautions to minimize health or environmental risk. As a condition of receiving the material, the customer agrees that any activity undertaken with the ATCC product and any progeny or modifications will be conducted in compliance with all applicable laws, regulations, and guidelines. This product is provided 'AS IS' with no representations or warranties whatsoever except as expressly set forth herein and in no event shall ATCC, its parents, subsidiaries, directors, officers, agents, employees, assigns, successors, and affiliates be liable for indirect, special, incidental, or consequential damages of any kind in connection with or arising out of the customer's use of the product. While reasonable effort is made to ensure authenticity and reliability of materials on deposit, ATCC is not liable for damages arising from the misidentification or misrepresentation of such materials.
Please see the material transfer agreement (MTA) for further details regarding the use of this product. The MTA is available at www.atcc.org.
Frequently Asked Questions
References
Curated Citations
García-López M, et al. Analysis of 1,000 Type-Strain Genomes Improves Taxonomic Classification of Bacteroidetes. Front Microbiol 10: 2083, 2019. PubMed: 31608019
For product-related inquiries and issues, contact Product Experience:
Hours of Operation
US Eastern Time