Happy Holidays!


We would like to inform you about our shipping schedule for the 2024 December holiday season.

ATCC will be closed from December 24, 2024 to January 1, 2025. To ensure timely delivery, please submit orders in accordance with the following:


  • Domestic orders no later than December 13th for shipment by December 20, 2024
  • International orders no later than December 11, 2024 for shipment by first week of January 2025

Thank you for your cooperation. We will resume our normal shipping schedule on January 2, 2025.

Contact Us
American Type Culture Collection (ATCC) Logo American Type Culture Collection (ATCC) Logo 0
  • Careers
  • Support

MG-63-GAS-Luc2

CRL-1427-GAS-LUC2

MG-63-GAS-Luc2 is a luciferase reporter-labeled cell line that endogenously expresses a high level of CD-155. This reporter cell line is useful for monitoring the activity of IFNγ-induced GAS signal transduction pathways.


Use promo code ATCC-000039 at checkout to save 10% on this product.*

*This offer is effective from October 1 – December 31, 2024. The 10% discount applies only to ATCC Checkpoint and CAR-T Target Reporter Models; all other items are excluded from this promotion. For non-profit customers, the promotional discount is applied to the customer-specific pricing. The promo code must be applied at the time of checkout. The promo code must be applied in the “Promotional code” field in the shopping cart. Void where prohibited. Restrictions may apply. Limit 20 vials.

Product category
Human cells
Product type
Cell model
Reporter-labeled cell
Organism
Homo sapiens, human
Tissue
Bone
Disease
Osteosarcoma
Applications
Immuno-oncology
Cancer research
Product format
Frozen
Storage conditions
Vapor phase of liquid nitrogen
Buy Now
Price: $1,285.00 ea
Discounts may be available for our fellow nonprofit organizations. Login to see your price.

Generally ships within 1-3 business days

Documentation

ATCC determines the biosafety level of a material based on our risk assessment as guided by the current edition of Biosafety in Microbiological and Biomedical Laboratories (BMBL), U.S. Department of Health and Human Services. It is your responsibility to understand the hazards associated with the material per your organization’s policies and procedures as well as any other applicable regulations as enforced by your local or national agencies.

ATCC highly recommends that appropriate personal protective equipment is always used when handling vials. For cultures that require storage in liquid nitrogen, it is important to note that some vials may leak when submersed in liquid nitrogen and will slowly fill with liquid nitrogen. Upon thawing, the conversion of the liquid nitrogen back to its gas phase may result in the vial exploding or blowing off its cap with dangerous force creating flying debris. Unless necessary, ATCC recommends that these cultures be stored in the vapor phase of liquid nitrogen rather than submersed in liquid nitrogen.

Required Products

These products are vital for the proper use of this item and have been confirmed as effective in supporting functionality. If you use alternative products, the quality and effectiveness of the item may be affected.

Detailed product information

General

Specific applications
Enabling sensitive and quantitative assessment of signal transduction makes this reporter cell line ideal for in vitro bioluminescence assays to study signaling pathways and the development of new checkpoint inhibitors for immuno-oncology drug discovery.

Characteristics

Cells per vial
6.0 to 8.0 x 106
Volume
1.0 mL
Growth properties
Adherent
Age
14 years
Ethnicity
White
Gender
Male
Karyotype
This is a hypotriploid human cell line. The modal chromosome number was 66 occurring in 44% of cells. The rate of cells with higher ploidies was 2.0%. Eighteen to 19 marker chromosomes were common to all cells.
Oncogene
Fibroblast-like
Antigen expression
CD-155
Comments
MG-63-GAS-Luc2 luciferase reporter cell line was derived from parental line MG-63 (ATCC CRL-1427) by stably expressing firefly luciferase gene (luc2) under control of a gamma -activated site (GAS) promoter. This cell line was established through lentiviral transduction and single cell cloning. The cells, upon stimulation, express high levels of enzymatically active luciferase protein, which can be detected via in vitro bioluminescence assays. This reporter cell line is useful for monitoring the activity of interferon gamma-induced signal transduction pathways.

Handling information

Complete medium
The base medium for this cell line is ATCC®-formulated Eagle's Minimum Essential Medium (ATCC 30-2003). To make the complete growth medium, add the following components to the base medium: heat-inactivated fetal bovine serum (FBS; ATCC 30-2020) to a final concentration of 10% and puromycin to a final concentration of 0.5 µg/mL.
Temperature
37°C
Atmosphere
95% Air, 5% CO2
Handling procedure

To ensure the highest level of viability, thaw the vial and initiate the culture as soon as possible upon receipt. If upon arrival, continued storage of the frozen culture is necessary, it should be stored in liquid nitrogen vapor phase and not at -70°C.  Storage at -70°C will result in loss of viability.  

  1. Thaw the vial by gentle agitation in a 37°C water bath. To reduce the possibility of contamination, keep the O-ring and cap out of the water.  Thawing should be rapid (approximately 2 minutes).
  2. Remove the vial from the water bath as soon as the contents are thawed, and decontaminate by dipping in or spraying with 70% ethanol. All of the operations from this point on should be carried out under strict aseptic conditions.
  3. It is recommended that the cryoprotective agent be removed immediately. Transfer the vial contents to a centrifuge tube containing 9.0 mL complete culture medium and spin at approximately 125 x g for 5 to 10 minutes.
  4. 4. Resuspend cell pellet with the recommended complete medium (see the specific batch information for the culture recommended dilution ratio) and dispense into a 25 cm2 or a 75 cm2 culture flask. It is important to avoid excessive alkalinity of the medium during recovery of the cells. It is suggested that, prior to the addition of the vial contents, the culture vessel containing the complete growth medium be placed into the incubator for at least 15 minutes to allow the medium to reach its normal pH (7.0 to 7.6)
  5. Incubate the culture at 37°C in a suitable incubator.  A 5% CO2 in air atmosphere is recommended if using the medium described on this product sheet.

         

Subculturing procedure
Volumes used in this protocol are for 75 cm2 flask; proportionally reduce or increase amount of dissociation medium for culture vessels of other sizes. Corning® T-75 flasks (catalog #430641) are recommended for subculturing this product.
  1. 1. Remove and discard culture medium.
  2. 2. Briefly rinse the cell layer with 0.25% (w/v) Trypsin- 0.53 mM EDTA solution to remove all traces of serum that contains trypsin inhibitor.
  3. 3. Add 2.0 to 3.0 mL of Trypsin-EDTA solution to flask and observe cells under an inverted microscope until cell layer is dispersed (usually within 5 to 15 minutes).
    Note: To avoid clumping do not agitate the cells by hitting or shaking the flask while waiting for the cells to detach. Cells that are difficult to detach may be placed at 37°C to facilitate dispersal.
  4. 4. Add 6.0 to 8.0 mL of complete growth medium and aspirate cells by gently pipetting.
  5. 5. Transfer cell suspension to centrifuge tube and spin at approximately 125 x g for 5 to 10 minutes.
  6. 6. Discard supernatant and resuspend cells in fresh growth medium. Add appropriate aliquots of cell suspension to new culture vessels. An inoculum of 5 x 103 to 7 x 103 viable cells/cm2 is recommended.
  7. 7. Place culture vessels in incubators at 37°C. Maintain cultures at a cell concentration between 3 x 104 and 5 x 104 cells/cm2.
  8. Incubate cultures at 37°C.
Subcultivation Ratio: A subcultivation ratio of 1:4 to 1:8 is recommended
Medium Renewal: 2 to 3 times a week
Reagents for cryopreservation
Complete growth medium supplemented with 5% (v/v) DMSO (ATCC 4-X)

Quality control specifications

Bacterial and fungal testing
Not detected
Mycoplasma contamination
Not detected
Virus testing
Cytomegalovirus (CMV): Not detected
Epstein-Barr virus (EBV): Not detected
Hepatitis B virus (HBV): Not detected
Human Immunodeficiency virus (HIV): Not detected
Human papillomavirus (HPV): Not detected
Functional tests
Luciferase assay: ≥ 10-fold increase in activity, basal to stimulation
STR profiling
Amelogenin: X,Y
CSF1PO: 10,12
D13S317: 11
D16S539: 11
D5S818: 11,12
D7S820: 10
THO1: 9.3
TPOX: 8,11
vWA: 16,19

History

Depositors
ATCC
Year of origin
2022

Legal disclaimers

Intended use
This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use.
Warranty

The product is provided 'AS IS' and the viability of ATCC® products is warranted for 30 days from the date of shipment, provided that the customer has stored and handled the product according to the information included on the product information sheet, website, and Certificate of Analysis. For living cultures, ATCC lists the media formulation and reagents that have been found to be effective for the product. While other unspecified media and reagents may also produce satisfactory results, a change in the ATCC and/or depositor-recommended protocols may affect the recovery, growth, and/or function of the product. If an alternative medium formulation or reagent is used, the ATCC warranty for viability is no longer valid.  Except as expressly set forth herein, no other warranties of any kind are provided, express or implied, including, but not limited to, any implied warranties of merchantability, fitness for a particular purpose, manufacture according to cGMP standards, typicality, safety, accuracy, and/or noninfringement.

Disclaimers

This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use. Any proposed commercial use is prohibited without a license from ATCC.

While ATCC uses reasonable efforts to include accurate and up-to-date information on this product sheet, ATCC makes no warranties or representations as to its accuracy. Citations from scientific literature and patents are provided for informational purposes only. ATCC does not warrant that such information has been confirmed to be accurate or complete and the customer bears the sole responsibility of confirming the accuracy and completeness of any such information.

This product is sent on the condition that the customer is responsible for and assumes all risk and responsibility in connection with the receipt, handling, storage, disposal, and use of the ATCC product including without limitation taking all appropriate safety and handling precautions to minimize health or environmental risk. As a condition of receiving the material, the customer agrees that any activity undertaken with the ATCC product and any progeny or modifications will be conducted in compliance with all applicable laws, regulations, and guidelines. This product is provided 'AS IS' with no representations or warranties whatsoever except as expressly set forth herein and in no event shall ATCC, its parents, subsidiaries, directors, officers, agents, employees, assigns, successors, and affiliates be liable for indirect, special, incidental, or consequential damages of any kind in connection with or arising out of the customer's use of the product. While reasonable effort is made to ensure authenticity and reliability of materials on deposit, ATCC is not liable for damages arising from the misidentification or misrepresentation of such materials.

Please see the material transfer agreement (MTA) for further details regarding the use of this product. The MTA is available at www.atcc.org.

Permits & Restrictions

Material Transfer Agreement Addendum for Screening Applications

For-profit organizations
For every order of this item, you must provide a signed Material Transfer Agreement Addendum for Screening Applications. We cannot ship this item until we receive this addendum. The person signing the addendum as the principal investigator must match the end user as listed on the applicable sales order for the item.

Email the signed addendum to [email protected] with a reference to both your account and sales order numbers. Once received, your addendum will be reviewed, and this item will be released for shipment if all requirements are met. Additional fees may apply if this product is being used for a screening use (ATCC ACS-2103F), and these fees will be applied after your order is confirmed. If you need assistance with your order, please contact our Customer Care team or your applicable distributor.

This material is subject to the following restrictions in addition to those outlined in the ATCC Material Transfer Agreement:

  1. Luciferase Label License 

For information on obtaining additional rights, please contact:

ATCC Licensing
Email: [email protected]

MORE INFORMATION ABOUT PERMITS AND RESTRICTIONS

Frequently Asked Questions

References

Curated Citations

Chang H, et al. GAS-Luc2 Reporter Cell Lines for Immune Checkpoint Drug Screening in Solid Tumors. Cancers 2024, 16, 1965. https://doi.org/10.3390/cancers16111965

Billiau A, et al. Human interferon: mass production in a newly established cell line, MG-63. Antimicrob. Agents Chemother. 12: 11-15, 1977. PubMed: 883813

Takeuchi Y, et al. Relationship between actions of transforming growth factor (TGF)-beta and cell surface expression of its receptors in clonal osteoblastic cells. J. Cell. Physiol. 162: 315-321, 1995. PubMed: 7860639

Yee A, et al. Biochemical characterization of the human cyclin-dependent protein kinase activating kinase. J. Biol. Chem. 271: 471-477, 1996. PubMed: 8550604

For product-related inquiries and issues, contact Technical Service:

Message Us

Hours of Operation

Monday - Friday
9:00am - 5:00pm
US Eastern Time