ATCC ATCC Logo 0
  • Careers
  • Support

Ectromelia virus

VR-1374

Product category
Viruses
Product type
Animal virus
Classification
Poxviridae, Orthopoxvirus
Strain designation
Moscow
Isolation source
Spleen homogenate from BALB/c mouse 6 days post-infection.
Product format
Frozen
Storage conditions
-70°C or colder
Buy Now
Price: $667.00 EA
Discounts may be available for our fellow nonprofit organizations. Login to see your price.

Generally ships within 1-3 business days

Documentation

ATCC determines the biosafety level of a material based on our risk assessment as guided by the current edition of Biosafety in Microbiological and Biomedical Laboratories (BMBL), U.S. Department of Health and Human Services. It is your responsibility to understand the hazards associated with the material per your organization’s policies and procedures as well as any other applicable regulations as enforced by your local or national agencies.

ATCC highly recommends that appropriate personal protective equipment is always used when handling vials. For cultures that require storage in liquid nitrogen, it is important to note that some vials may leak when submersed in liquid nitrogen and will slowly fill with liquid nitrogen. Upon thawing, the conversion of the liquid nitrogen back to its gas phase may result in the vial exploding or blowing off its cap with dangerous force creating flying debris. Unless necessary, ATCC recommends that these cultures be stored in the vapor phase of liquid nitrogen rather than submersed in liquid nitrogen.

Required Products

These products are vital for the proper use of this item and have been confirmed as effective in supporting functionality. If you use alternative products, the quality and effectiveness of the item may be affected.

Detailed product information

General

Specific applications
1982. Mousepox, (in) The Mouse in Biomedical Research: Vol.
Requests for the agent must carry a signed statement assuming all risk and responsibility for handling and use.

Characteristics

Comments
Inadvertent introduction of Ectromelia virus into mouse colonies has caused major outbreaks in US animal colonies. The depositor recommends that animal care and biosafety management at your institution be consulted prior to initiating work with this agent. Requests for the agent must carry a signed statement assuming all risk and responsibility for handling and use. For additional information see: Fenner. 1982. Mousepox, (in) The Mouse in Biomedical Research: Vol. II. Diseases, (ed) Foster et al., Academic Press.
Mycoplasma contamination
Not detected

Handling information

Host
Effects
cell rounding; CPE; death of host animal
Complete medium
EMEM (ATCC® 30-2003™) + 2% FBS (ATCC® 30-2020™)
Temperature
37°C
Atmosphere
95% Air, 5% CO2
Incubation
1 to 7 days at 37°C, a 5% CO2 in air atmosphere is recommended
Recommendation for infection
For best results cells should be 24 to 48 hours old and 80% - 90% confluent (not 100% confluent).
Handling notes
Inadvertent introduction of Ectromelia virus into mouse colonies has caused major outbreaks in US animal colonies. The depositor recommends that animal care and biosafety management at your institution be consulted prior to initiating work with this agent. Requests for the agent must carry a signed statement assuming all risk and responsibility for handling and use. For additional information see: Fenner, 1982. Mousepox. (in) The Mouse in Biomedical Research: Vol. II. Diseases. (ed) Foster et al., Academic Press.

Key abbreviations
°C, Degrees Celsius
BS-C-1, African green monkey kidney cells
CO2, Carbon dioxide
CPE, Cytopathic effect
EMEM, Eagle's Minimum Essential Medium
FBS, Fetal bovine serum

History

Deposited as
Ectromelia virus
Depositors
RM Buller
Type of isolate
Animal
Cross references
GenBank AF012825 Ectromelia virus envelope glycoprotein C1R (C1R), C2R (C2R), C3R (C3R), IFN-gamma binding protein C4R (C4R), C5R (C5R), protein kinase C6R (C6R), serpin C7R (C7R), C8R (C8R), IL-1 beta binding protein C9R (C9R), C10L (C10L), C11R (C11R), IFN-...

Legal disclaimers

Intended use
This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use.
Warranty

The product is provided 'AS IS' and the viability of ATCC® products is warranted for 30 days from the date of shipment, provided that the customer has stored and handled the product according to the information included on the product information sheet, website, and Certificate of Analysis. For living cultures, ATCC lists the media formulation and reagents that have been found to be effective for the product. While other unspecified media and reagents may also produce satisfactory results, a change in the ATCC and/or depositor-recommended protocols may affect the recovery, growth, and/or function of the product. If an alternative medium formulation or reagent is used, the ATCC warranty for viability is no longer valid.  Except as expressly set forth herein, no other warranties of any kind are provided, express or implied, including, but not limited to, any implied warranties of merchantability, fitness for a particular purpose, manufacture according to cGMP standards, typicality, safety, accuracy, and/or noninfringement.

Disclaimers

This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use. Any proposed commercial use is prohibited without a license from ATCC.

While ATCC uses reasonable efforts to include accurate and up-to-date information on this product sheet, ATCC makes no warranties or representations as to its accuracy. Citations from scientific literature and patents are provided for informational purposes only. ATCC does not warrant that such information has been confirmed to be accurate or complete and the customer bears the sole responsibility of confirming the accuracy and completeness of any such information.

This product is sent on the condition that the customer is responsible for and assumes all risk and responsibility in connection with the receipt, handling, storage, disposal, and use of the ATCC product including without limitation taking all appropriate safety and handling precautions to minimize health or environmental risk. As a condition of receiving the material, the customer agrees that any activity undertaken with the ATCC product and any progeny or modifications will be conducted in compliance with all applicable laws, regulations, and guidelines. This product is provided 'AS IS' with no representations or warranties whatsoever except as expressly set forth herein and in no event shall ATCC, its parents, subsidiaries, directors, officers, agents, employees, assigns, successors, and affiliates be liable for indirect, special, incidental, or consequential damages of any kind in connection with or arising out of the customer's use of the product. While reasonable effort is made to ensure authenticity and reliability of materials on deposit, ATCC is not liable for damages arising from the misidentification or misrepresentation of such materials.

Please see the material transfer agreement (MTA) for further details regarding the use of this product. The MTA is available at www.atcc.org.

Permits & Restrictions

Import Permit for the State of Hawaii

If shipping to the U.S. state of Hawaii, you must provide either an import permit or documentation stating that an import permit is not required. We cannot ship this item until we receive this documentation. Contact the Hawaii Department of Agriculture (HDOA), Plant Industry Division, Plant Quarantine Branch to determine if an import permit is required.

MORE INFORMATION ABOUT PERMITS AND RESTRICTIONS

Frequently Asked Questions

References

Curated Citations

Chen W, et al. Restricted replication of ectromelia virus in cell culture correlates with mutations in virus-encoded host range gene. Virology 187: 433-442, 1992. PubMed: 1546448

Need assistance with this product? Contact our Technical Support team.

Telephone

US and Puerto Rico
800-638-6597

Outside the US
+1-703-365-2700

Hours of Operation

Monday-Friday
9:00am - 5:00pm
US Eastern Time