- Product category
-
Bacteria
- Strain designation
- Seattle 1945
- Type strain
- No
- Genome sequenced strain
- Yes
- Isolation source
- Clinical isolate
- Applications
-
BioinformaticsEnteric disease researchInfectious disease researchMedia testingQuality controlWater testing
- Product format
- Frozen
- Shipping information
- 6 ready-to-use vials containing the strain in glycerol stock
- Storage conditions
-
-80°C or colder
Documentation
ATCC determines the biosafety level of a material based on our risk assessment as guided by the current edition of Biosafety in Microbiological and Biomedical Laboratories (BMBL), U.S. Department of Health and Human Services. It is your responsibility to understand the hazards associated with the material per your organization’s policies and procedures as well as any other applicable regulations as enforced by your local or national agencies.
ATCC highly recommends that appropriate personal protective equipment is always used when handling vials. For cultures that require storage in liquid nitrogen, it is important to note that some vials may leak when submersed in liquid nitrogen and will slowly fill with liquid nitrogen. Upon thawing, the conversion of the liquid nitrogen back to its gas phase may result in the vial exploding or blowing off its cap with dangerous force creating flying debris. Unless necessary, ATCC recommends that these cultures be stored in the vapor phase of liquid nitrogen rather than submersed in liquid nitrogen.
Detailed product information
General
- Specific applications
-
ATCC® 25923-MINI-PACK™ consists of 6 ready-to-use vials of ATCC® 25923™ frozen in 200 µL of glycerol stock, eliminating the need to rehydrate and culture the strain prior to use. Each vial is provided with a 2-D barcode for easy storage and tracking, as well as peel-off labels for fast and reliable recordkeeping. Developed by the leaders in microbial cultivation and preservation, ATCC® Minis provide a convenient, ready-to-use solution for handling quality control strains. ATCC® Minis are authenticated and backed by ATCC polyphasic testing – ensuring the same consistent and reliable reference materials you’ve come to trust for ATCC Genuine Cultures®. It is easy to ensure the quality of your products with ATCC® Minis – just open, plate, and go!
CAMP testAssay of wood smoke concentrateControl strainControl strain for identificationEvaluation of Mueller-Hinton agarExamination of dairy productsMedia testingQuality control strainReference materialSusceptibility disc testingEnteric ResearchWater testingSusceptibility disc testing ampicillinSusceptibility disc testing caryomycinSusceptibility disc testing cephalexinSusceptibility disc testing cephaloglycinSusceptibility disc testing cephaloridine cephalomycinSusceptibility disc testing cephalothinSusceptibility disc testing chloramphenicolSusceptibility disc testing erythromycinSusceptibility disc testing gentamicins gentamicinSusceptibility disc testing kanamycinSusceptibility disc testing novobiocinSusceptibility disc testing tetracyclineSusceptibility testingCAMP test for Listeria monocytogenesQuality control strain for Abbott, and Autobac products - Preceptrol
- No
Characteristics
- Comments
- Incorrectly cited in previous editions of this catalog as identical to NCTC 6571.
Handling information
- Medium
- Temperature
-
37°C
- Atmosphere
-
Aerobic
- Handling procedure
-
Frozen mini-cryovials packed in dry ice should either be thawed immediately for use or stored at or below
-70°C until the expiration date printed on the label. Storage at -20°C is acceptable for up to 1 year.- Thaw the bacterial strain upright using gentle agitation in a 25°C to 30°C water bath. Thawing will be rapid; approximately 2-3 minutes or until all ice crystals have melted.
- Immediately after thawing, wipe down the mini-cryovial with 70% ethanol and aseptically transfer the entire contents to a 5-6 mL tube of #18 broth or directly inoculate a #18 plate and/or #18 agar slant.
- Discard the empty vial. Do not refreeze any unused portion as it will result in a loss of viability.
- Incubate at 37°C for 24 hours.
- Handling notes
-
On sheep blood agar plates, beta-hemolysis is observed. It is advisable to transfer from agar to agar to maintain MIC values.
Several GenBank accessions are available for this item:
- Nucleotide (GenBank) : AF053568 Staphylococcus aureus ATCC 25923 heat shock protein 60 gene, partial cds.
- Nucleotide (GenBank) : AX110511 Sequence 1244 from Patent WO0123604.
- Nucleotide (GenBank) : AX110995 Sequence 1728 from Patent WO0123604.
- Nucleotide (GenBank) : U02910 Staphylococcus aureus ATCC 25923 16S rRNA gene, partial sequence.
- Nucleotide (GenBank) : U39769 Staphylococcus aureus 16S-23S ribosomal RNA spacer region.
- Nucleotide (GenBank) : Z16422 S.aureus dfrB gene for dihydrofolate reductase.
- Nucleotide (GenBank) : AB047239 Staphylococcus aureus DNA, complete structure of cassette chromosome(SCC)-like element, strain:ATCC 25923.
Additional information on this culture is available on the ATCC® web site at www.atcc.org.
Quality control specifications
- Verification method
-
Whole-genome Sequencing
History
- Deposited as
- Staphylococcus aureus Rosenbach
- Depositors
- FDA
- Chain of custody
- ATCC <-- FDA <-- F Schoenknecht
- Special collection
-
ATCC® Minis
- Cross references
-
GenBank AX110511 Sequence 1244 from Patent WO0123604.GenBank AX110995 Sequence 1728 from Patent WO0123604.GenBank Z16422 S.aureus dfrB gene for dihydrofolate reductase.GenBank U39769 Staphylococcus aureus 16S-23S ribosomal RNA spacer region.GenBank U02910 Staphylococcus aureus ATCC 25923 16S rRNA gene, partial sequence.GenBank AF053568 Staphylococcus aureus ATCC 25923 heat shock protein 60 gene, partial cds.GenBank AB047239 Staphylococcus aureus DNA, complete structure of cassette chromosome(SCC)-like element, strain:ATCC25923.
Legal disclaimers
- Intended use
- This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use.
- Warranty
-
The product is provided 'AS IS' and the viability of ATCC® products is warranted for 30 days from the date of shipment, provided that the customer has stored and handled the product according to the information included on the product information sheet, website, and Certificate of Analysis. For living cultures, ATCC lists the media formulation and reagents that have been found to be effective for the product. While other unspecified media and reagents may also produce satisfactory results, a change in the ATCC and/or depositor-recommended protocols may affect the recovery, growth, and/or function of the product. If an alternative medium formulation or reagent is used, the ATCC warranty for viability is no longer valid. Except as expressly set forth herein, no other warranties of any kind are provided, express or implied, including, but not limited to, any implied warranties of merchantability, fitness for a particular purpose, manufacture according to cGMP standards, typicality, safety, accuracy, and/or noninfringement.
- Disclaimers
-
This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use. Any proposed commercial use is prohibited without a license from ATCC.
While ATCC uses reasonable efforts to include accurate and up-to-date information on this product sheet, ATCC makes no warranties or representations as to its accuracy. Citations from scientific literature and patents are provided for informational purposes only. ATCC does not warrant that such information has been confirmed to be accurate or complete and the customer bears the sole responsibility of confirming the accuracy and completeness of any such information.
This product is sent on the condition that the customer is responsible for and assumes all risk and responsibility in connection with the receipt, handling, storage, disposal, and use of the ATCC product including without limitation taking all appropriate safety and handling precautions to minimize health or environmental risk. As a condition of receiving the material, the customer agrees that any activity undertaken with the ATCC product and any progeny or modifications will be conducted in compliance with all applicable laws, regulations, and guidelines. This product is provided 'AS IS' with no representations or warranties whatsoever except as expressly set forth herein and in no event shall ATCC, its parents, subsidiaries, directors, officers, agents, employees, assigns, successors, and affiliates be liable for indirect, special, incidental, or consequential damages of any kind in connection with or arising out of the customer's use of the product. While reasonable effort is made to ensure authenticity and reliability of materials on deposit, ATCC is not liable for damages arising from the misidentification or misrepresentation of such materials.
Please see the material transfer agreement (MTA) for further details regarding the use of this product. The MTA is available at www.atcc.org.
Frequently Asked Questions
References
Curated Citations
Performance Standards for Antimicrobial Disk Susceptibility Tests; Approved Standard - 9th Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M2-A9.
Protocols for Evaluating Dehydrated Mueller-Hinton Agar; Approved Standard. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M6-A2.
Methods for Dilution Antimicrobial Susceptibility Tests for Bacteria that Grow Aerobically; Approved Standard - 7th Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M7-A8.
Methodology for the Serum Bactericidal test: Approved Guideline. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M21-A.
Quality Control for Commercially Prepared Microbiological Culture Media; Approved Standard - 3rd Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M22-A3.
For product-related inquiries and issues, contact Product Experience:
Hours of Operation
US Eastern Time