Bacteria
- Product type
-
Drug-resistant bacterium
- Classification
- Actinomycetia, Corynebacteriales
- Strain designation
- BCG Russia Strep-R rpsL K43R
- Type strain
- No
- Geographical isolation
- Canada
- Applications
-
Agricultural researchAntimicrobial resistance researchInfectious disease researchRespiratory disease research
- Product format
- Frozen
- Storage conditions
-
-80°C or colder
Documentation
ATCC determines the biosafety level of a material based on our risk assessment as guided by the current edition of Biosafety in Microbiological and Biomedical Laboratories (BMBL), U.S. Department of Health and Human Services. It is your responsibility to understand the hazards associated with the material per your organization’s policies and procedures as well as any other applicable regulations as enforced by your local or national agencies.
ATCC highly recommends that appropriate personal protective equipment is always used when handling vials. For cultures that require storage in liquid nitrogen, it is important to note that some vials may leak when submersed in liquid nitrogen and will slowly fill with liquid nitrogen. Upon thawing, the conversion of the liquid nitrogen back to its gas phase may result in the vial exploding or blowing off its cap with dangerous force creating flying debris. Unless necessary, ATCC recommends that these cultures be stored in the vapor phase of liquid nitrogen rather than submersed in liquid nitrogen.
Detailed product information
General
- Specific applications
- This strain serves as a safe QC reagent for TB diagnostics and drug‑susceptibility testing workflows.
- Preceptrol
- No
Characteristics
- Susceptibility profile
-
Resistant
Streptomycin
- Comments
- Recombineering techniques were used by the depositor to introduce a K43R mutation in rpsL into the wild-type BCG Russia strain, conferring resistance to streptomycin.
Handling information
- Medium
- Temperature
-
37°C
- Atmosphere
-
Aerobic
- Handling procedure
-
- Open thawed vial.
- Aseptically transfer the entire contents to a 5-6 mL tube of #1395 broth. Additional test tubes can be inoculated by transferring 0.5 mL of the primary broth tube to these secondary tubes.
- Use several drops of the primary broth tube to inoculate a #1561 plate and/or #1561 agar slant.
- Incubate at 37°C for 2-4 weeks.
- Handling notes
- Medium #1395 should be used for dilution and transfer only. Medium #1561 should be used for growth of culture to maintain streptomycin resistance.
Quality control specifications
- Volume
- 0.5 mL
History
- Deposited as
- Mycobacterium bovis
- Depositors
- Marcel Behr, McGill University Health Centre
- Year of origin
- 2019
Legal disclaimers
- Intended use
- This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use.
- Warranty
-
The product is provided 'AS IS' and the viability of ATCC® products is warranted for 30 days from the date of shipment, provided that the customer has stored and handled the product according to the information included on the product information sheet, website, and Certificate of Analysis. For living cultures, ATCC lists the media formulation and reagents that have been found to be effective for the product. While other unspecified media and reagents may also produce satisfactory results, a change in the ATCC and/or depositor-recommended protocols may affect the recovery, growth, and/or function of the product. If an alternative medium formulation or reagent is used, the ATCC warranty for viability is no longer valid. Except as expressly set forth herein, no other warranties of any kind are provided, express or implied, including, but not limited to, any implied warranties of merchantability, fitness for a particular purpose, manufacture according to cGMP standards, typicality, safety, accuracy, and/or noninfringement.
- Disclaimers
-
This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use. Any proposed commercial use is prohibited without a license from ATCC.
While ATCC uses reasonable efforts to include accurate and up-to-date information on this product sheet, ATCC makes no warranties or representations as to its accuracy. Citations from scientific literature and patents are provided for informational purposes only. ATCC does not warrant that such information has been confirmed to be accurate or complete and the customer bears the sole responsibility of confirming the accuracy and completeness of any such information.
This product is sent on the condition that the customer is responsible for and assumes all risk and responsibility in connection with the receipt, handling, storage, disposal, and use of the ATCC product including without limitation taking all appropriate safety and handling precautions to minimize health or environmental risk. As a condition of receiving the material, the customer agrees that any activity undertaken with the ATCC product and any progeny or modifications will be conducted in compliance with all applicable laws, regulations, and guidelines. This product is provided 'AS IS' with no representations or warranties whatsoever except as expressly set forth herein and in no event shall ATCC, its parents, subsidiaries, directors, officers, agents, employees, assigns, successors, and affiliates be liable for indirect, special, incidental, or consequential damages of any kind in connection with or arising out of the customer's use of the product. While reasonable effort is made to ensure authenticity and reliability of materials on deposit, ATCC is not liable for damages arising from the misidentification or misrepresentation of such materials.
Please see the material transfer agreement (MTA) for further details regarding the use of this product. The MTA is available at www.atcc.org.
Permits & Restrictions
Import Permit for the State of Hawaii
If shipping to the U.S. state of Hawaii, you must provide either an import permit or documentation stating that an import permit is not required. We cannot ship this item until we receive this documentation. Contact the Hawaii Department of Agriculture (HDOA), Plant Industry Division, Plant Quarantine Branch to determine if an import permit is required.
Permit to Import Infectious Biological Agents, Infectious Substances, and Vectors
For every order of this item, you must provide a valid Permit to Import Infectious Biological Agents, Infectious Substances, and Vectors (CDC 0728) obtained from the United States Department of Health and Human Services, Centers for Disease Control and Prevention (CDC). We cannot ship this item until we receive this permit.
USDA Organisms and Vectors Interstate Permit
For every order of this item requiring interstate transport, you must provide a valid Permit for Importation and Transportation of Controlled Materials and Organisms and Vectors (VS Form 16-6A) obtained from the United States Department of Agriculture (USDA), Animal and Plant Health Inspection Service. For information on filling out VS Form 16-6A, read our compliance and domestic shipment document to learn the common mistakes to avoid.
Frequently Asked Questions
References
Curated Citations
Danchuk SN, et al. Bacillus Calmette-Guérin strains with defined resistance mutations: a new tool for tuberculosis laboratory quality control. Clin Microbiol Infect 26(3): 384.e5-384.e8, 2020. PubMed: 31705996
For product-related inquiries and issues, contact Product Experience:
Hours of Operation
US Eastern Time