- Clone type
- Vector
- Applications
-
Molecular biology
- Product format
- Freeze-dried
Documentation
ATCC determines the biosafety level of a material based on our risk assessment as guided by the current edition of Biosafety in Microbiological and Biomedical Laboratories (BMBL), U.S. Department of Health and Human Services. It is your responsibility to understand the hazards associated with the material per your organization’s policies and procedures as well as any other applicable regulations as enforced by your local or national agencies.
Detailed product information
General
- Specific applications
-
vector containing primer sites useful for sequencingvector for generating nested deletions of cloned insertsvector permitting visual detection of recombinants
Characteristics
- Comments
-
Restriction digests of the clone give the following sizes (kb): EcoRI--11.5; NdeI--5.5, 4.2, 1.8; PvuII--5.8, 3.15, 0.78 (doublet), 0.66, 0.28; PstI--8.4, 2.1, 0.96.Plasmid contains the following restriction sites (approximate kb from nt 1): BamHI--6.86; BglI--6.49, 7.42, 7.65, 9.97, 11.18; EcoRI-3.77; HindIII--2.25; NdeI--2.96, 4.74, 8.79; PstI--0.65, 1.72, 10.10; PvuI--5.50, 10.22; SalI--7.14; SmaI--0.93, 4.50.A series of overlapping deletion segments can be generated by partial digestion with a restriction enzyme not found in the vector, followed by complete digestion with lambda terminase.Resulting fragments are blunted and circularized by ligation, and transformants are selected for either ampicillin or kanamycin resistance.IMPORTANT: To prevent amplification of a rearranged and/or deleted cosmid, we recommend streaking on LB + amp plates at 30C and picking small colonies for liquid culture.Cosmid vector containing two compatible origins of replication, for generating bidirectional deletions of large inserts to facilitate sequencing.AmpR transformants can be sequenced in the clockwise direction using the cosL primer 5'-TCATAAATAGCGAAAACC-3'. KanR transformants can be sequenced in the counterclockwise direction using the cosR primer 5'-ACTTTACGGGTCCTTTCCG-3'.The order of the major features in the plasmid is: ren - P - O - ori lambda - cII - cro - kanR - cosR/L - ampR - oriP - tetR.
- Mycoplasma contamination
- Not detected
Vector information
- Construct size (kb)
- 11.58100032806397
- Vector name
- pDO19 (cosmid)
- Construction
- pDO17
- Vector information
-
other: lambda cos site
- Markers
-
kanR; ampR; tetR
- Replicon
- lambda; oriP
Handling information
- Temperature
-
30°C
History
- Depositors
- A Ahmed
- Special collection
-
NCRR Contract
- Cross references
-
GenBank U03461
Legal disclaimers
- Intended use
- This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use.
- Warranty
-
The product is provided 'AS IS' and the viability of ATCC® products is warranted for 30 days from the date of shipment, provided that the customer has stored and handled the product according to the information included on the product information sheet, website, and Certificate of Analysis. For living cultures, ATCC lists the media formulation and reagents that have been found to be effective for the product. While other unspecified media and reagents may also produce satisfactory results, a change in the ATCC and/or depositor-recommended protocols may affect the recovery, growth, and/or function of the product. If an alternative medium formulation or reagent is used, the ATCC warranty for viability is no longer valid. Except as expressly set forth herein, no other warranties of any kind are provided, express or implied, including, but not limited to, any implied warranties of merchantability, fitness for a particular purpose, manufacture according to cGMP standards, typicality, safety, accuracy, and/or noninfringement.
- Disclaimers
-
This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use. Any proposed commercial use is prohibited without a license from ATCC.
While ATCC uses reasonable efforts to include accurate and up-to-date information on this product sheet, ATCC makes no warranties or representations as to its accuracy. Citations from scientific literature and patents are provided for informational purposes only. ATCC does not warrant that such information has been confirmed to be accurate or complete and the customer bears the sole responsibility of confirming the accuracy and completeness of any such information.
This product is sent on the condition that the customer is responsible for and assumes all risk and responsibility in connection with the receipt, handling, storage, disposal, and use of the ATCC product including without limitation taking all appropriate safety and handling precautions to minimize health or environmental risk. As a condition of receiving the material, the customer agrees that any activity undertaken with the ATCC product and any progeny or modifications will be conducted in compliance with all applicable laws, regulations, and guidelines. This product is provided 'AS IS' with no representations or warranties whatsoever except as expressly set forth herein and in no event shall ATCC, its parents, subsidiaries, directors, officers, agents, employees, assigns, successors, and affiliates be liable for indirect, special, incidental, or consequential damages of any kind in connection with or arising out of the customer's use of the product. While reasonable effort is made to ensure authenticity and reliability of materials on deposit, ATCC is not liable for damages arising from the misidentification or misrepresentation of such materials.
Please see the material transfer agreement (MTA) for further details regarding the use of this product. The MTA is available at www.atcc.org.
Images
Frequently Asked Questions
References
Curated Citations
Ahmed A. Double-origin vectors for isolating bidirectional deletions useful in DNA sequence analysis. Gene 141: 71-73, 1994. PubMed: 8163177
For product-related inquiries and issues, contact Product Experience:
Hours of Operation
US Eastern Time