- Organism
-
Homo sapiens, human
- Clone type
- Clone
- Applications
-
Molecular biology
- Product format
- Freeze-dried
Documentation
ATCC determines the biosafety level of a material based on our risk assessment as guided by the current edition of Biosafety in Microbiological and Biomedical Laboratories (BMBL), U.S. Department of Health and Human Services. It is your responsibility to understand the hazards associated with the material per your organization’s policies and procedures as well as any other applicable regulations as enforced by your local or national agencies.
Detailed product information
Characteristics
- Comments
-
Restriction digests of the clone give the following sizes (kb): BamHI--3.5; EcoRI--3.4; PstI--3.0, 0.6; BamHI/SstI--2.8, 0.7.Of 93 obligate carriers for hemophilia A, 35 were informative for the BclI RFLP (exon 17-18). Of 39 obligate carriers NOT detected by p114.12, 19 were informative with p482.6 (intron 22/XbaI).Insert includes exons 17-18 extending slightly 3' to exon 18 but not as far as the polymorphic BclI site.BclI polymorphism maps to intron 18.Enzyme(s) not detecting polymorphism: AhaIII, ApaI, AvaII, BamHI, BamHII, BglI, BstEII, BstXI, EcoRI, EcoRII, EcoRV, HaeIII, HincIII, HindIII, HinfI, HpaI, KpnI, MspI, MciI, NcoI, NsiI, PstI, PvuII, RsaI, Sau3AI, Sau96I, ScaI, ScrFI, SphI, and others.
- Mycoplasma contamination
- Not detected
Vector information
- Construct size (kb)
- 3.0
Insert information
- Insert size (kb)
- 0.64700000000000002
- Type of DNA
- genomic
- Gene product
- coagulation factor VIIIc, procoagulant component (hemophilia A) [F8C]
- Alleles
- F3, E1, E1, E2, F1, F2, A1, A2
Handling information
- Medium
- Temperature
-
37°C
Legal disclaimers
- Intended use
- This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use.
- Warranty
-
The product is provided 'AS IS' and the viability of ATCC® products is warranted for 30 days from the date of shipment, provided that the customer has stored and handled the product according to the information included on the product information sheet, website, and Certificate of Analysis. For living cultures, ATCC lists the media formulation and reagents that have been found to be effective for the product. While other unspecified media and reagents may also produce satisfactory results, a change in the ATCC and/or depositor-recommended protocols may affect the recovery, growth, and/or function of the product. If an alternative medium formulation or reagent is used, the ATCC warranty for viability is no longer valid. Except as expressly set forth herein, no other warranties of any kind are provided, express or implied, including, but not limited to, any implied warranties of merchantability, fitness for a particular purpose, manufacture according to cGMP standards, typicality, safety, accuracy, and/or noninfringement.
- Disclaimers
-
This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use. Any proposed commercial use is prohibited without a license from ATCC.
While ATCC uses reasonable efforts to include accurate and up-to-date information on this product sheet, ATCC makes no warranties or representations as to its accuracy. Citations from scientific literature and patents are provided for informational purposes only. ATCC does not warrant that such information has been confirmed to be accurate or complete and the customer bears the sole responsibility of confirming the accuracy and completeness of any such information.
This product is sent on the condition that the customer is responsible for and assumes all risk and responsibility in connection with the receipt, handling, storage, disposal, and use of the ATCC product including without limitation taking all appropriate safety and handling precautions to minimize health or environmental risk. As a condition of receiving the material, the customer agrees that any activity undertaken with the ATCC product and any progeny or modifications will be conducted in compliance with all applicable laws, regulations, and guidelines. This product is provided 'AS IS' with no representations or warranties whatsoever except as expressly set forth herein and in no event shall ATCC, its parents, subsidiaries, directors, officers, agents, employees, assigns, successors, and affiliates be liable for indirect, special, incidental, or consequential damages of any kind in connection with or arising out of the customer's use of the product. While reasonable effort is made to ensure authenticity and reliability of materials on deposit, ATCC is not liable for damages arising from the misidentification or misrepresentation of such materials.
Please see the material transfer agreement (MTA) for further details regarding the use of this product. The MTA is available at www.atcc.org.
Frequently Asked Questions
References
Curated Citations
Drayna D, et al. Genetic mapping and diagnosis of haemophilia A achieved through a BclI polymorphism in the factor VIII gene. Nature 314: 738-740, 1985. PubMed: 2986011
Gitschier J, et al. Antenatal diagnosis and carrier detection of haemophilia A using factor VIII gene probe. Lancet 1: 1093-1094, 1985. PubMed: 2860301
Wood WI, et al. Expression of active human factor VIII from recombinant DNA clones. Nature 312: 330-337, 1984. PubMed: 6438526
Janco RL, et al. Improved efficacy of carrier assignment in hemophilia A using intragenic probes. Am. J. Hum. Genet. 39: A95, 1986.