Escherichia coli (Migula) Castellani and Chalmers (ATCC® 35218)

Strain Designations: 1532  /  Type Strain: no  /  Biosafety Level: 1

Permits And Restrictions

View Permits

Classification Enterobacteriaceae, Escherichia
Strain Designations 1532
Application
Assay of lactam antibiotics beta-lactam antibiotics
Evaluation of Mueller-Hinton agar
Quality control strain
Susceptibility disc testing
Susceptibility testing
Quality control strain for API, bioMerieux Vitek and Sensititre products
Isolation
Canine, Tennessee
Type Strain no
Biosafety Level 1
Product Format freeze-dried
Storage Conditions Frozen: -80°C or colder
Freeze-Dried: 2°C to 8°C
Live Culture: See Propagation Section
Preceptrol® yes
Type Strain no
Medium ATCC® Medium 3: Nutrient agar or nutrient broth
Growth Conditions
Temperature: 37°C
Atmosphere: Aerobic
Name of Depositor FS Barr
Isolation
Canine, Tennessee
References

Performance Standards for Antimicrobial Disk Susceptibility Tests; Approved Standard - 9th Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M2-A9.

Protocols for Evaluating Dehydrated Mueller-Hinton Agar; Approved Standard. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M6-A2.

Methods for Dilution Antimicrobial Susceptibility Tests for Bacteria that Grow Aerobically; Approved Standard - 7th Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M7-A8.

Performance Standards for Antimicrobial Disk and Dilution Susceptibility Tests for Bacteria Isolated from Animals; Approved Standard - 2nd Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M31-A3.

Performance Standards for Antimicrobial Susceptibility Testing; Sixteenth Informational Supplement. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M100-S20, 2007

BD Phoenix Gram Negative AST NMIC/ID QC Set. BD Becton Dickinson; Phoenix

MicroScan Dried Gram Positive Panel QC Set. Dade/Siemens.

MicroScan Dried Gram Negative Panel QC Set. Dade/Siemens.

MicroScan Rapid Gram Negative QC Set. Dade/Siemens.

Sensititre™ MIC Susceptibility. Thermo Scientific™ Sensititre™ Systems, Trek Diagnostic Systems.

Susceptibility Testing of Mycobacteria, Nocardiae, and Other Aerobic Actinomycetes; Approved Standard. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M24-A.

Methods for Antimicrobial Disk Susceptibility Testing of Bacteria Isolated from Aquatic Animals. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M42-A.

Methods for Antimicrobial Dilution and Disk susceptibility Testing of Infrequently Isolated or Fastidious Bacteria: Proposed Guideline. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M45-A.

Medical microbiology -- Susceptibility testing of microbial pathogens to antimicrobial agents -- Part 81: Microdilution; Special requirements for testing of non-fastidious bacteria. Berlin, Germany: Deutsches Institut fur Normung; DIN 58940-81: 2002

Clinical laboratory testing and in vitro diagnostic test systems --- Susceptibility testing of infectious agents and evaluation of performance of antimicrobial susceptibility test devices --- Part 1: Reference method for testing the in vitro activity of antimicrobial agents against rapidly growing aerobic bacteria involved in infectious diseases. London, UK:British Standards Institution;British Standard BS EN ISO 20776-1:2006.

VITEK 2 AST-GN QC Set. bioMerieux.

VITEK 2 AST-GP QC Set. bioMerieux.

MicroScan Synergies plus Gram Negative QC Set. Dade/Siemens.

ETEST ESBL STRIP. bioMerieux.

Sensititre™ MIC Breakpoint QC Set/5. Thermo Scientific™ Sensititre™ Systems, Trek Diagnostic Systems.

Notice: Necessary PermitsPermits

These permits may be required for shipping this product:

  • Customers located in the state of Hawaii will need to contact the Hawaii Department of Agriculture to determine if an Import Permit is required. A copy of the permit or documentation that a permit is not required must be sent to ATCC in advance of shipment.
Basic Documentation