ATCC ATCC Logo 0
  • Careers
  • Support

Escherichia coli (Migula) Castellani and Chalmers

CRM-11229

Download Genome Learn about the ATCC Genome Portal
Product category
Bacteria
Product type
Certified reference material
Classification
Enterobacteriaceae, Escherichia
Strain designation
AMC 198
Type strain
No
Genome sequenced strain
Yes
Applications
Assay development
Bioinformatics
Product format
Freeze-dried
Buy Now
Price: $539.00 EA
Discounts may be available for our fellow nonprofit organizations. Login to see your price.

Generally ships within 1-3 business days

Documentation

ATCC determines the biosafety level of a material based on our risk assessment as guided by the current edition of Biosafety in Microbiological and Biomedical Laboratories (BMBL), U.S. Department of Health and Human Services. It is your responsibility to understand the hazards associated with the material per your organization’s policies and procedures as well as any other applicable regulations as enforced by your local or national agencies.

ATCC highly recommends that appropriate personal protective equipment is always used when handling vials. For cultures that require storage in liquid nitrogen, it is important to note that some vials may leak when submersed in liquid nitrogen and will slowly fill with liquid nitrogen. Upon thawing, the conversion of the liquid nitrogen back to its gas phase may result in the vial exploding or blowing off its cap with dangerous force creating flying debris. Unless necessary, ATCC recommends that these cultures be stored in the vapor phase of liquid nitrogen rather than submersed in liquid nitrogen.

Detailed product information

General

Specific applications
For use in testing and calibration in ISO 17025 accredited laboratories, to challenge assay performance, validate or compare test methods, and to establish sensitivity, linearity and specificity during assay validation or implementation. 
Bacterial resistance testing paint
Membrane filter testing
Testing
Testing absorbent pads
Testing antimicrobial handwashing formulations
Testing disinfectants
Testing ink grids
Testing sanitizers
Preceptrol
No

Characteristics

Comments

Certificates of Analysis are available electronically at www.atcc.org, or by hardcopy upon request.

Certified Reference Material produced under an ISO 17034 accredited process.

Handling information

Medium
Temperature
37°C
Atmosphere
Aerobic
Handling procedure
  1. Open vial according to enclosed instructions.
  2. From a single tube of #3 broth (5 to 6 mL), withdraw approximately 0.5 to 1.0 mL with a Pasteur or 1.0 mL pipette and use to rehydrate the entire pellet.
  3. Aseptically transfer the rehydrated pellet back into the broth tube.  Mix well.
  4. Use several drops of this suspension to inoculate a second tube of broth, a slant, and/or plate.
  5. Incubate the tubes and plate at 37oC for 24 hours.
Handling notes
Certificates of Analysis are available electronically at www.atcc.org, or by hardcopy upon request.

Additional information on this culture is available on the ATCC website at www.atcc.org.

Quality control specifications

Verification method
Whole-genome Sequencing
Quality accreditation

Manufactured under an ISO 17034 accredited process

    ACLASS Accredited Reference Material Producer AR-1384

History

Deposited as
Escherichia coli (Migula) Castellani and Chalmers
Depositors
AMC - Walter Reed Army Medical Center
Special collection
Certified Reference Materials

Legal disclaimers

Intended use
This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use.

Certified Reference Material produced under an ISO 17034 accredited process.

Warranty

The product is provided 'AS IS' and the viability of ATCC® products is warranted for 30 days from the date of shipment, provided that the customer has stored and handled the product according to the information included on the product information sheet, website, and Certificate of Analysis. For living cultures, ATCC lists the media formulation and reagents that have been found to be effective for the product. While other unspecified media and reagents may also produce satisfactory results, a change in the ATCC and/or depositor-recommended protocols may affect the recovery, growth, and/or function of the product. If an alternative medium formulation or reagent is used, the ATCC warranty for viability is no longer valid.  Except as expressly set forth herein, no other warranties of any kind are provided, express or implied, including, but not limited to, any implied warranties of merchantability, fitness for a particular purpose, manufacture according to cGMP standards, typicality, safety, accuracy, and/or noninfringement.

Disclaimers

This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use. Any proposed commercial use is prohibited without a license from ATCC.

While ATCC uses reasonable efforts to include accurate and up-to-date information on this product sheet, ATCC makes no warranties or representations as to its accuracy. Citations from scientific literature and patents are provided for informational purposes only. ATCC does not warrant that such information has been confirmed to be accurate or complete and the customer bears the sole responsibility of confirming the accuracy and completeness of any such information.

This product is sent on the condition that the customer is responsible for and assumes all risk and responsibility in connection with the receipt, handling, storage, disposal, and use of the ATCC product including without limitation taking all appropriate safety and handling precautions to minimize health or environmental risk. As a condition of receiving the material, the customer agrees that any activity undertaken with the ATCC product and any progeny or modifications will be conducted in compliance with all applicable laws, regulations, and guidelines. This product is provided 'AS IS' with no representations or warranties whatsoever except as expressly set forth herein and in no event shall ATCC, its parents, subsidiaries, directors, officers, agents, employees, assigns, successors, and affiliates be liable for indirect, special, incidental, or consequential damages of any kind in connection with or arising out of the customer's use of the product. While reasonable effort is made to ensure authenticity and reliability of materials on deposit, ATCC is not liable for damages arising from the misidentification or misrepresentation of such materials.

Please see the material transfer agreement (MTA) for further details regarding the use of this product. The MTA is available at www.atcc.org.

Permits & Restrictions

Import Permit for the State of Hawaii

If shipping to the U.S. state of Hawaii, you must provide either an import permit or documentation stating that an import permit is not required. We cannot ship this item until we receive this documentation. Contact the Hawaii Department of Agriculture (HDOA), Plant Industry Division, Plant Quarantine Branch to determine if an import permit is required.

MORE INFORMATION ABOUT PERMITS AND RESTRICTIONS

Frequently Asked Questions

References

Curated Citations

ASTM International Standard Test Method for Evaluation of Health Care Personnel Handwash Formulation. West Conshohocken, PA

ASTM International Standard Test Method for Evaluation of Antimicrobial Handwash Formulations by Utilizing Fingernail Regions. West Conshohocken, PA

ASTM International Standard Methods for Evaluating Absorbent Pads Used with Membrane Filters for Bacteriological Analysis and Growth. West Conshohocken, PA (Reapproved 2003).

ASTM International Standard Test Method for Evaluating Inhibitory Effects of Ink Grids on Membrane Filters. West Conshohocken, PA (Reapproved 2003).

AOAC International Germicidal and detergent sanitizing action of disinfectants. Gaithersburg, MD:AOAC International;AOAC "Official Methods of Analysis of the AOAC International" 960.09.

View All Curated Citations for this Product

Need assistance with this product? Contact our Technical Support team.

Telephone

US and Puerto Rico
800-638-6597

Outside the US
+1-703-365-2700

Hours of Operation

Monday-Friday
9:00am - 5:00pm
US Eastern Time