Staphylococcus aureus subsp. aureus Rosenbach (ATCC® 29213)

Strain Designations: Wichita  /  Type Strain: no  /  Biosafety Level: 2

Permits And Restrictions

View Permits

Strain Designations Wichita
Application
Quality control strain
Susceptibility disc testing
Susceptibility testing
Quality control strain for API, BBL, bioMerieux Vitek, Micro-Media, MicroScan®, and Sensititre products
Drug discovery
Enteric Research
Isolation
Wound
Type Strain no
Biosafety Level 2
Product Format freeze-dried
Storage Conditions Frozen: -80°C or colder
Freeze-Dried: 2°C to 8°C
Live Culture: See Propagation Section
Preceptrol® yes
Type Strain no
Antibiotic Resistance
Sensitive to oxacillin
Comments Sensitive to oxacillin
Medium ATCC® Medium 18: Trypticase Soy Agar/Broth
Growth Conditions
Temperature: 37°C
Atmosphere: Aerobic
Name of Depositor Micro-Media Systems, Inc.
Chain of Custody
ATCC <-- Micro-Media Systems, Inc. <-- EH Gerlach strain Wichita
Isolation
Wound
References

Performance Standards for Antimicrobial Disk Susceptibility Tests; Approved Standard - 9th Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M2-A9.

Methods for Dilution Antimicrobial Susceptibility Tests for Bacteria that Grow Aerobically; Approved Standard - 7th Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M7-A8.

Performance Standards for Antimicrobial Disk and Dilution Susceptibility Tests for Bacteria Isolated from Animals; Approved Standard - 2nd Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M31-A3.

Performance Standards for Antimicrobial Susceptibility Testing; Sixteenth Informational Supplement. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M100-S20, 2007

API ID 32 STAPH. bioMerieux.

BD Phoenix Gram Positive AST PMIC/ID QC Set. BD Becton Dickinson; Phoenix

MicroScan Dried Gram Positive Panel QC Set. Dade/Siemens.

MicroScan Dried Gram Negative Panel QC Set. Dade/Siemens.

Sensititre™ MIC Susceptibility. Thermo Scientific™ Sensititre™ Systems, Trek Diagnostic Systems.

Sensititre™ Mycobacterium Susceptibility. Thermo Scientific™ Sensititre™ Systems, Trek Diagnostic Systems.

Susceptibility Testing of Mycobacteria, Nocardiae, and Other Aerobic Actinomycetes; Approved Standard. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M24-A.

Susceptibility Testing of Mycobacteria, Nocardiae, and Other Aerobic Actinomycetes; Table 9 Supplement. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M24-S1.

Evaluation of Lots of Dehydrated Mueller-Hinton Broth for Antimicrobial Susceptibility testing; Proposed Guideline. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M32-P.

Methods for Antimicrobial Dilution and Disk susceptibility Testing of Infrequently Isolated or Fastidious Bacteria: Proposed Guideline. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M45-A.

Methods for Broth Dilution Susceptibility Testing of Bacteria Isolated from Aquatic Animals. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M49-A.

Medical microbiology; methods for the determination of susceptibility of pathogens (except mycobacteria) to antimicrobial agents: agar diffusion test. Berlin, Germany: Deutsches Institut fur Normung; DIN 58940-3: 1989

Medical microbiology -- Methods for the determination of susceptibility of pathogens (except mycobacteria) to antimicrobial agents-- Part 7: Determination of the minimum bactericidal concentration (MBC) with the aid of microdilution. Berlin, Germany:Deutsches Institut fur Normung;DIN DIN 58940-7: 1994, 1994

Medical microbiology: methods for the determination of susceptibility of pathogens (except mycobacteria) to antimicrobial agents; determination of MICs by agar dilution method. Berlin, Germany:Deutsches Institut fur Normung;DIN DIN 58940-6: 1989, 1989

Medical microbiology -- Susceptibility testing of microbial pathogens to antimicrobial agents -- Part 81: Microdilution; Special requirements for testing of non-fastidious bacteria. Berlin, Germany: Deutsches Institut fur Normung; DIN 58940-81: 2002

Clinical laboratory testing and in vitro diagnostic test systems --- Susceptibility testing of infectious agents and evaluation of performance of antimicrobial susceptibility test devices --- Part 1: Reference method for testing the in vitro activity of antimicrobial agents against rapidly growing aerobic bacteria involved in infectious diseases. London, UK:British Standards Institution;British Standard BS EN ISO 20776-1:2006.

VITEK 2 AST-GP QC Set. bioMerieux.

MicroScan Synergies plus Gram Positive QC Set. Dade/Siemens.

ISO/CD 11133:2009, Annex E. Test microorganisms for commonly used culture media (giving information on the culture medium, culture conditions, test microorganisms, culture collection number of test organisms and the expected reactions)

Corry, JEL, Curtis, GDW and Baird, RM (Eds) Handbook of Culture Media for Food and Water Microbiology. Royal Society of Chemistry, In preparation. ICFMH-WPCM.

Sensititre™ MIC Breakpoint QC Set/5. Thermo Scientific™ Sensititre™ Systems, Trek Diagnostic Systems.

BD MAX™ StaphSR Assay. BD Becton Dickinson.

Cross References

Nucleotide (GenBank) : U77328 Staphylococcus aureus staphylokinase gene, partial cds.

Notice: Necessary PermitsPermits

These permits may be required for shipping this product:

  • Customers located in the state of Hawaii will need to contact the Hawaii Department of Agriculture to determine if an Import Permit is required. A copy of the permit or documentation that a permit is not required must be sent to ATCC in advance of shipment.
Basic Documentation